Thermocouple Calibrator PCE-TTC 30 in Pakistan
- Brand: PCE Instruments Germany
- Product Code: PCE-TTC 30
- Availability: Pre-Order
-
Rs.0
Thermocouple Calibrator to simulate and measure thermocouples, current, and voltage / Li-Ion battery / Continuity tester / Ramp function.
Specification:
| Voltage DC V | |||
| Measuring range | Resolution | Accuracy | |
| 0 ... 30V | 0.001V | ± 0.02% of reading + 2 Dgt | |
| Current DC mA | |||
| Measuring range | Resolution | Accuracy | |
| 0 ... 24-mA | 0.001-mA | ± 0.02% of reading + 2 Dgt | |
| Measurement / Simulation | |||
| Thermocouples | Measuring range | Resolution | Accuracy |
| E | -200 ... 1200°C / -328 ... 2192°F | 0.1°C / 0.18°F | ± 0.3°C / 0.54°F |
| J | -200 ... 1200°C / -328 ... 2192°F | 0.1°C / 0.18°F | ± 0.3°C / 0.54°F |
| K | -200 ... 1372°C / -328 ... 2501°F | 0.1°C / 0.18°F | ± 0.3°C / 0.54°F |
| T | -200 ... 400°C / -328 ... 752°F | 0.1°C / 0.18°F | ± 0.3°C / 0.54°F |
| B | 450 ... 1800°C / 842 ... 3272°F | 0.1°C / 0.18°F | ± 0.3°C / 0.54°F |
| R | 0 ... 1750°C / 32 ... 3182°F | 0.1°C / 0.18°F | ± 0.3°C / 0.54°F |
| S | 0 ... 1750°C / 32 ... 3182°F | 0.1°C / 0.18°F | ± 0.3°C / 0.54°F |
| N | -200 ... 1300°C / -328 ... 2372°F | 0.1°C / 0.18°F | ± 0.3°C / 0.54°F |
| mV | 10 ... 80 mV | 0.001 mV | ± 0.02% of reading + 2μV |
-10 ... 250 mV | 0.01 mV | ± 0.02% of reading + 0.02 mV | |
| Note: The specifications refer to the temperature standard ITS-90 | |||
| General specifications | |||
| Display modes | Measurement: mA / V / thermocouple / mV Simulation: thermocouple / mV | ||
| Temperature units | °C / °F / K | ||
| Cold junction compensation error | ≤ ± 0.5°C / 0.9°F | ||
| Maximum input voltage | 30V DC | ||
| Temperature coefficient | <30 ppm | ||
| Input impedance measurement | Thermocouple / mV / V:> 1 MΩ Current measurement: 10 Ω | ||
| Response time | <100 ms | ||
| Impedance | > 4.7 kΩ with thermocouple / mV | ||
| Refresh rate display | 10 Hz | ||
| Isolation | 500V DC | ||
| Data storage | Internal memory 150000 readings | ||
| Interface | USB 2.0 | ||
| Display | 2.4" TFT LCD 240 x 320 pixels LED illuminated | ||
| Output voltage current loop | 24V DC / 24mA | ||
| HART mA loop resistance | 250 Ω ± 20% | ||
| Special features | Step and ramp function Automatic and manual mode √x, x2: For the measuring function | ||
| Continuity test | Adjustable threshold up to 100 Ω | ||
| Power supply | 3.7V / 2300mAh Li-ion battery | ||
| Charging time | about 5 h | ||
| Power adapter | Input: 100 ... 240V AC / 50/60 Hz Output: 5V / 1 A DC | ||
| Battery life | Approx. 15 h: Simulation and measurement with low LCD illumination Approx. 8 h: Measurement with low LCD illumination | ||
| Dimensions | 162 x 82 x 40 mm | ||
| Weight | About 300 g / < 1 lb | ||
| Degree of protection | IP20 | ||
| Operating conditions | Battery operation: 0 ... 55°C / 32 ... 131°F, 30 ... 90% RH Main operation: 0 ... 45°C / 32 ... 113 °F, 30 ... 90% RH | ||
| Storage conditions | -20 .. 60°C / -4 ... 140°F, 30 ... 90% rh non-condensing | ||
| Heating time | About 15 minutes | ||
Delivery Scope:
1 x Thermocouple Calibrator PCE-TTC 30
2 x Laboratory cables with 2 mm plug
1 x Thermocouple adapter to 2 mm plug
2 x Adapter 2 mm on 4 mm laboratory cable
2 x Alligator clips
1 x Mini USB cable
1 x Power supply 5 V / 1 A
1 x Carrying bag
1 x Software
1 x User manual
Download the User Manual of PCE-TTC 30