Process calibrator PCE-MCA 50 Universal calibrator with powerful battery / Transducer for simulation and measurement / Generation of increments / Extensive measurement and simulation functions.

Specification:

  
Display modesMeasurement: mA / V / mV / mA (24V) / Switch test / Temperature thermocouple / Resistance thermometer / Frequency / Pulse
 Simulation: mA / V / mV / mA (2 W) / Resistance / Resistance Thermometer / Temperature Thermocouple / Frequency / Pulse
Maximum input voltage30V DC
Input impedance MeasurementThermocouple, mV, V, frequency, pulse: 1 MΩ
mA: 10 MΩ
Response time<100 ms
Load impedance> 4.7 KΩ for thermocouple / mV / V / pulse / frequency
<750 Ω for mA
Refresh rate display10 readings per second
Isolation500V DC
Data storage150000 measured values ​​maximum
InterfaceUSB 2.0
Display3.2" TFT LCD
240 x 320 pixels
LED illuminated
Output voltage Current loop24V DC / 24-mA
HART mA loop Resistance250 Ω ± 20%
Special featuresStep and ramp function
Automatic and manual
mode √x, x2: For the measuring function
Continuity testAdjustable threshold value up to 100 Ω
Power supplyRechargeable battery, 3000-mAh 3.7V
Charging timeMax. 5 hours
Power adapter100 ... 240V AC, 50/60 Hz, output 5V DC at 1 A
Battery life> 17 h: Simulation and measurement with low LCD illumination
> 9 h: Measurement with low LCD illumination
Dimensions (L x W x H)185.6 x 97.1 x 41.3 mm / 7.3 x 3.8 x 1.6 in
Weight<500 g / 1.1 lbs
Protection classIP20
Operating conditions0 ... 55°C / 32 ... 131°F, 30 ... 90% RH (non-condensing)
storage conditions-20 ... 60°C / -4 ... 140°F, 30 ... 90% rh (non-condensing)
Heating time5 minutes
  
Technical data electrical measurement
    
ParameterMeasuring rangeResolutionMeasurement accuracy
V0 ... 30V DC0.001V± 0.02% of v. Mw. ± 2 Dgt
mA0 ... 24-mA0.001-mA± 0.02% of v. Mw. ± 2 Dgt
    
Technical data electrical simulation
    
ParameterMeasuring rangeResolutionMeasurement accuracy
V0 ... 12V DC0.001V± 0.02% of v. Mw. ± 2 Dgt
mA0 ... 24-mA0.001-mA± 0.02% of v. Mw. ± 2 Dgt
    
Technical Data Measurement / Simulation Thermocouple mV
    
Type thermocoupleMeasuring rangeResolutionMeasurement accuracy
    
e-200 ... 1000°C /   -328 ... 1832°F0.1°C / 0.18°F± 0.3°C / 0.54°F
J-200 ... 1200°C /   -328 ... 2192°F0.1°C / 0.18°F± 0.3°C / 0.54°F
K-200 ... 1372°C / 0.1°C / 0.18°F± 0.3°C / 0.54°F
T-200 ... 400°C /    -328 ... 752°F0.1°C / 0.18°F± 0.3°C / 0.54°F
B450 ... 1800°C /     842 ... 3272°F0.1°C / 0.18°F± 0.5°C / 0.9°F
R0 ... 1750°C /           32 ... 3182°F0.1°C / 0.18°F± 0.5°C / 0.9°F
S0 ... 1750°C /           32 ... 3182°F0.1°C / 0.18°F± 0.5°C / 0.9°F
N-200 ... 1300°C /   -328 ... 2372°F0.1°C / 0.18°F± 0.3°C / 0.54°F
mV-10 ... 80 mV
-10 ... 250 mV
0.001 mV
0.01 mV
± 0.02% of v. Mw. ± 4 μm
± 0.02% of v. Mw. ± 0.02 mV
    
Technical data Frequency measurement 
  
Measuring rangeResolution
0.0143 ... 9.9999 Hz0.0001 Hz
10 ... 99,999 Hz0.001 Hz
100 ... 999.99 Hz0.01
1000 ... 9999.9 Hz0.1 Hz
10000 ... 50,000 Hz1 Hz
  
FunctionSpecification
  
Triggering threshold0 ... 12V in 1V increments
Measurement accuracy± 0.01% of v. Mw. ± 1 Dgt
Supported unitsHz, kHz, cph, cpm, sec., Msec., Μsec
  
Technical data Pulse counting 
  
FunctionSpecification
  
Measuring range0 ... 999999 pulses
Triggering threshold0 ... 12V in 1V increments
  
Technical data Frequency generation 
  
Measuring rangeResolution
  
0.0005 ... 0.5 Hz0.00001 Hz
0.5 ... 50 Hz0.0001 Hz
50 ... 500 Hz0.001 Hz
500 ... 5000 Hz0.01 Hz
5000 ... 10000 Hz0.1 Hz
  
FunctionSpecification
  
Output amplitude positive square wave0 ... 12V PP (± 0.5V)
Output amplitude symmetrical square wave0 ... 6V PP (± 0.5V)
Measurement accuracy± 0.02% of reading ± 2
Duty cycle1 ... 99% (up to 500 Hz)
Supported unitsHz, KHz, cph, cpm, sec., Msec., Μsec.
  
Technical data Pulse generation 
  
FunctionSpecification
  
Measuring range0 ... 999999 pulses
Resolution1 pulse
Output amplitude positive square wave0 ... 12V PP (± 0.5V PP)
Output amplitude symmetrical square wave0 ... 6V PP (± 0.5V PP)
Pulse frequency0.0005 ... 10000 Hz
Duty cycle1 ... 99% (up to 500 Hz)
  
Technical Data Measurement and Simulation 
  
ParameterMeasuring rangeResolutionMeasurement accuracy
    
Resistance (Ω)0 ... 400 Ω0.01 Ω4-wire measurement: ± 0.02% of vol. Mw. ± 0.01Ω
Simulation: ± 0.02% v. Mw ± 0.02 Ω
 400 ... 4000 Ω0.1 Ω4-wire measurement: ± 0.02% of vol. Mw. ± 0.1Ω
Simulation: ± 0.02% of v. Mw ± 0.15 Ω
 -200 ... 200°C /  -328 ... 392°FPt10 ... Pt400: 0.01°C / 0.018°F4-wire measurement: ± 0.15°C / 0.27°F
Simulation: ± 0.15°C / 0.27°F
Pt10 ... Pt100200 ... 600°C /     392 ... 1112°F
600 ... 850°C /   1112 ... 1532°F
Pt500 ... Pt1000: 0.1°C / 0.18°F4-wire measurement: ± 0.3°C / 0.54°F
Simulation: ± 0.35°C / 0.63°F
Ni100-60 ... 180°C /      -76 ... 356°F0.01°C / 0.018°FSimulation: ± 0.35°C / 0.63°F
4-wire measurement: ± 0.1°C / 0.18°F
Ni120-80 ... 260°C /    -112 ... 500°F0.01°C / 0.018°FSimulation: ± 0.15°C / 0.27°F
Cu10 ... Cu100