Measurement values | Measurement ranges / resolution / accuracy |
PCE-830 + PCE-6801 Watts AC (50 Hz or 60 Hz, PF 0.5 up to 1) | 5.0 W to 999.9 W / 0.1 W / ±1% ±0.8 W 1.000 kW to 9.999 kW / 0.001 kW / ±1% ±8 W 10.00 kW to 99.99 kW / 0.01 kW / ±1% ±80 W 100.0 kW to 999.9 kW / 0.1 kW / ±1% ±0.8 kW 1,000 kW to 9,999 kW / 1 kW / ±1% ±8 kW |
PCE-830 + PCE-6802 Watts AC (50 Hz or 60 Hz, PF 0.5 up to 1) | 5.0 W to 999.9 W / 0.1 W / ±1% ±0.8 W 1.000 kW to 9.999 kW / 0.001 kW / ±1% ±8 W 10.00 kW to 99.99 kW / 0.01 kW / ±1% ±80 W 100.0 kW to 999.9 kW / 0.1 kW / ±1% ±0.8 kW 1000 kW to 9999 kW / 1 kW / ±1% ±8 kW 0.000 MW to 9.999 MW / 0.001 MW / ±1% ±80 kW |
PCE-830 + PCE-3007 Watts AC (50 Hz or 60 Hz, PF 0.5 up to 1) | 10.0 W to 999.9 W / 0.1 W / ±1% of measurement range 1.000 kW to 9.999 kW / 0.001 kW / ±1% of measurement range 10.00 kW to 99.99 kW / 0.01 kW / ±1% of measurement range 100.0 kW to 999.9 kW / 0.1 kW / ±1% of measurement range 1,000 kW to 9,999 kW / 1 kW / ±1% of measurement range |
PCE-830 + PCE-6801 Current AC (50 Hz or 60 Hz, auto range select, TRMS) | 0.04 A to 1 A / 0.001 A / ±0.5% ±0.05 A 0.4 A to 10.0 A / 0.01 A / ±0.5% ±0.05 A 4 A to 100.0 A / 0.1 A / ±1.0% ±0.5 A |
PCE-830 + PCE-6802 Current AC (50 Hz or 60 Hz, auto range select, TRMS) | 10.00 A / 0.01 A / 4 A to 100.0 A / 0.01 A / ±0.5% ±0.5 A 40 A to 1000.0 A / 0.1 A / ±0.5% ±5 A |
PCE-830 + PCE-3007 Current AC (50 Hz or 60 Hz, auto range select, TRMS) | 0 to 300 A / 0.1 A / ±1.0% of measurement range 300.0 A to 999.9 A / 0.1 A / ±1.0% of measurement range 1,000 A to 3,000 A / 1 A / ±1.0% of measurement range |
Voltage AC (50 Hz or 60 Hz, TRMS) | 20.0 V ... 500.0 V / 0.1 V / ±0.5 % ±5 digits (grounded) 20.0 V ... 600.0 V / 0.1 V / ±0.5 % ±5 digits (phase to phase) |
Harmonic distortionof AC voltage | 1º to 20º / 0.1% / ±1.0% 21º to 49º / 0.1% / 4% of reading ±2.0% 50º to 99º / 0.1% / 6% of reading ±2.0% |
PCE-830 + PCE-6801 Harmonics of AC current in % | 1º to 20º / 0.1% / ±0.2% of reading ±1.0% 11º to 20º / 0.1% / ±2% of reading ±1.0% 21º to 50º (A)/ 0.1% / ±5% of reading ±1.0% 21º to 50º (mA)/ 0.1% / ±10% of reading ±1.0% 51º to 99º / 0.1% / ±35% of reading ±1.0% |
PCE-830 + PCE-6802 Harmonics of AC current in % | 1º to 10º / 0.1% / ±2% 21º to 49º / 0.1% / 4% of reading ±2.0% 50º to 99º / 0.1% / 6% of reading ±2.0% |
PCE-830 + PCE-3007 Harmonics of AC current in % | 1º to 10º / 0.1% / ±2% 21º to 49º / 0.1% / ±6% 50º to 99º / 0.1% / ±10% |
PCE-830 + PCE-6801 / PCE-830 + PCE-6802 Power Factor (PF) | 0.00 to 1.00 / 0.01 / ±0.04 |
PCE-830 + PCE-3007 Power Factor (PF) | 0.000 to 1,000 / 0.001 / ±0.04 |
PCE-830 + PCE-6801 / PCE-830 + PCE-6802 Phase angle (Phi) | -180° to 180° / 0.1° / ±1° |
PCE-830 + PCE-3007 Phase angle (Phi) | 0° to 180° / 0.1° / ±2° |
PCE-830 + PCE-6801 Total harmonic distortion | 0.0 to 20.0% / 0.1% / ±1% 20.0% to 100% / 0.1% / ±3% of reading ±5% 100% to 999.9% / 0.1% / ±10% of reading ±10% |
PCE-830 + PCE-6802 Total harmonic distortion | 0.0 to 20.0% / 0.1% / ±2% 20.0% to 100% / 0.1% / ±6% of reading ±1% 100% to 999.9% / 0.1% / ±10% of reading ±1% |
PCE-830 + PCE-3007 Total harmonic distortion | 0.0 to 20.0% / 0.1% / ±2% 20.0% to 100% / 0.1% / ±6% of reading ±1% 100% to 999.9% / 0.1% / ±10% of reading ±1% |
Maximum measurement of AC voltage and current | 50 Hz / 19 µS / ±5% ±30 digits 60 Hz / 16 µS / ±5% ±30 digits |
Peak value measurement of AC voltage and current | 1.00 to 99.99 / 0.01 / ±5% ±30 digits |
Frequency range in automatic mode | 45 Hz to 65 Hz / 0.1 H z / 0.1 Hz |
Memory | 512 kB for a maximum 52,420 readings taken by 1 phase / 2 conductors |
Port | USB |
Software and cable | included, for Windows 2000, XP, ME |
Display | backlit LCD with dot matrix |
Power | 8 AA batteries (Mignon) |
Dimensions | 257 mm x 155 mm x 57 mm 10.1 in x 6.10 in x 2.24 in |
Weight | 1.16 kg / 2.56 lbs |
Operating conditions | max. 85% relative humidity -10º C to 50º C / 14º F to 122º F |
Type of protection / standards | IEC 61010, 600 V/CAT III |
Set 1: PCE-830 + PCE-6801 amp clamp (100 A) - Electrical conductor pick-up: 30 mm / 1.2 in diameter - Range selection: manual (1 A, 10 A, 100 A) - Dimensions: 210 mm x 62 mm x 36 mm / 8.2 in x 2.4 in x 1.4 in - Weight: 200 g / 7 oz | |
Set 2: PCE-830 + PCE-6802 amp clamp (1000 A) - Electrical conductor pick-up: 55 mm / 2.2 in diameter - Range selection: manual (10 A, 100 A, 1,000 A) - Dimensions: 244 mm x 97 mm x 46 mm / 8.6 in x 97 in x 46 in - Weight: 600 g / 1.3 lbs | |
Set 3: PCE-830 + PCE-3007 flexible amp clamp (3000 A) - Electrical conductor pick-up: 170 mm / 6.69 in diameter - Minimum radial curve : 35 mm / 1.4 in - Length of electrical conductor: 610 mm / 24.0 in - Diameter of electrical conductor: 14 mm / 0.55 in - Dimensions (Box): 130 mm x 80 mm x 43 mm / 5.1 in x 3.1 in x 1.6 in - Weight: 410 g / 14.4 oz | |
Outline of the PCE-830 | |
Connecting the amp clamps to the PCE-830: 1. Turn on the device. 2. Push the "1f3f" key until "3P3W" appears on the display for 3 phases / 3 conductors. 3. Connect the 3 test cables from the voltage with L1, L2, L3 and the analyser. The amp clamps are connected, as seen in the image to the right, between the device and the circuit. 4. The results can then be seen on the display. |
Delivery Scope:
1 x PCE-830-2 Power Analyzer
3 x Amp clamps - Depending on set ordered (PCE-6801, PCE-6802, or PCE-3007)
4 x Alligator clips
4 x Safety test lines (3 m / 3.3 ft long)
8 x Batteries
1 x Mains adaptor
1 x Carrying case
1 x USB cable software