Clamp Meter PCE-DC 25 in Pakistan

Clamp Meter PCE-DC 25 in Pakistan

  • Rs.0



Clamp meter with Bluetooth interface / Current measurement 0 ... 1000 A AC/DC / Temperature measurement / NCV test / Clamp opening 34 mm (1.3") / Measuring rate of 3 Hz /Optionally expandable with Rogowski coil for 3000 A AC / Automatic switch-off.

Specification:

DC voltage 
Measuring range600.0 mV DC
Resolution0.1 mV DC
Accuracy±(0.5 % + 8 digits)
  
Measuring range6.000 V DC
Resolution0.001 V DC
Accuracy±(1.5 % + 5 digits)
  
Measuring range60.00 V DC
Resolution0.01 V DC
Accuracy±(1.5 % + 5 digits)
  
Measuring range600.0 V DC
Resolution0.1 V DC
Accuracy±(1.5 % + 5 digits)
  
Measuring range1000 V DC
Resolution1 V
Accuracy±(1.5 % + 5 digits)
  
Input impedance>10 MΩ
Overvoltage protection1000 V AC/DC
  
AC voltage
Measuring range6.000 V AC
Resolution0.001 V AC
Accuracy±(1.5 % + 5 digits)
  
Measuring range60.00 V AC
Resolution0.01 V AC
Accuracy±(1.5 % + 5 digits)
  
Measuring range600.0 V AC
Resolution0.1 V AC
Accuracy±(1.5 % + 5 digits)
  
Measuring range1000 V AC
Resolution1 V AC
Accuracy±(1.5 % + 5 digits)
  
Peak value (PEAK) accuracy±10 %
Peak value (PEAK) response time1 ms
Input impedance>10 MΩ
Overvoltage protection1000 V AC/DC
  
The accuracy relates to a measuring range of 10 ... 100 %
with a sine wave.
Low pass filter (LowZ)
(50 ... 400 Hz)
 
Measuring range6.000 V AC
Resolution0.001 V AC
Accuracy±(3.0 % + 40 digits)
  
Measuring range60.00 V AC
Resolution0.01 V AC
Accuracy±(3.0 % + 40 digits)
  
Measuring range300.0 V AC
Resolution0.1 V
Accuracy±(3.0 % + 40 digits)
  
Input impedance<300 kΩ
Overvoltage protection1000 V AC/DC
  
The accuracy relates to a measuring range of 10 ... 100 %
with a sine wave.
AC with DC voltage
(50 ... 400 Hz)
 
Measuring range6.000 V AC
Resolution0.001 V AC
Accuracy±(2.5 % + 20 digits)
  
Measuring range60.00 V AC
Resolution0.01 V AC
Accuracy±(2.5 % + 20 digits)
  
Measuring range600.0 V AC
Resolution0.1 V AC
Accuracy±(2.5 % + 20 digits)
  
Measuring range1000 V AC
Resolution1 V AC
Accuracy±(2.5 % + 20 digits)
  
Input impedance>10 MΩ
  
Direct current 
Measuring range600.0 A DC
Resolution0.1 A DC
Accuracy±(2.5 % + 5 digits)
  
Measuring range1000 A DC
Resolution1 A DC
Accuracy±(2.8 % + 5 digits)
  
Overvoltage protection1000 A DC
  
Alternating current
(50 ... 60 Hz)
 
Measuring range600.0 A AC
Resolution0.1 A AC
Accuracy±(2.5 % + 5 digits)
  
Measuring range1000 A AC
Resolution1 A AC
Accuracy±(2.8 % + 5 digits)
  
Overload protection1000 A AC/DC
  
Flexible clamp meter
(50 ... 400 Hz)
 
Measuring range30.00 A AC
Resolution0.01 A AC
Accuracy±(3.0 % + 5 digits)
  
Measuring range300.0 A AC
Resolution0.1 A AC
Accuracy±(3.0 % + 5 digits)
  
Measuring range3000 A AC
Resolution1 A AC
Accuracy±(3.0 % + 5 digits)
  
Overload protection3000 A AC/DC
  
The accuracy relates to a measuring range of 10 ... 100 %
with a sine wave.
Resistance 
Measuring range600.0 Ω
Resolution0.1 Ω
Accuracy±(1.0 % + 10 digits)
  
Measuring range6.000 kΩ
Resolution0.001 kΩ
Accuracy±(1.5 % + 5 digits)
  
Measuring range60.00 kΩ
Resolution0.01 kΩ
Accuracy±(1.5 % + 5 digits)


Measuring range600.0 kΩ
Resolution0.1 kΩ
Accuracy±(1.5 % + 5 digits)
  
Measuring range6.000 MΩ
Resolution0.001 MΩ
Accuracy±(2.5 % + 5 digits)
  
Measuring range60.00 MΩ
Resolution0.01 MΩ
Accuracy±(3.5 % + 10 digits)
  
Overvoltage protection1000 V AC/DC


Continuity test 
Signal<50 Ω
Overvoltage protection1000 V AC/DC
  
Diode test
Test current<1.5 mA
Maximum tension when open
circuit
3.3 V DC
  
Frequency measurement 
Measuring range9.999 Hz ... 99.99 kHz
Resolution0.01 ... 10 Hz
Accuracy±(1.2 % + 5 digits)
  
Overvoltage protection1000 V AC/DC
  
Sensitivity>5 Vrms with one duty cycle
  from 20 ... 80 %
Duty cycle 
Measuring range10.0 ... 90.0 %
Resolution0.1 %
Accuracy±(1.2 % + 8 digits)
  
Pulse range40 Hz ... 10 kHz
Pulse amplitude±5 V (0.1 ... 100 ms)
  
Capacity 
Measuring range60.00 nF
Resolution0.01 nF
Accuracy±(4.0 % + 20 digits)
  
Measuring range600.0 nF
Resolution0.1 nF
Accuracy±(3.0 % + 8 digits)
  
Measuring range6.000 µF
Resolution0.001 µF
Accuracy±(3.0 % + 8 digits)


Measuring range60.00 µF
Resolution0.01 µF
Accuracy±(3.0 % + 8 digits)
  
Measuring range600.0 µF
Resolution0.1 µF
Accuracy±(3.0 % + 8 digits)
  
Measuring range6000 µF
Resolution1 µF
Accuracy±(5.0 % + 8 digits)
  
Measuring range60.00 mF
Resolution0.01 mF
Accuracy±(5.0 % + 20 digits)
  
Measuring range100.0 mF
Resolution0.1 mF
Accuracy±(5.0 % + 20 digits)
  
Overvoltage protection1000 V AC/DC
  
Temperature measurement
(Thermocouple Type K)
 
Measuring range-40 ... 600.0 °C
Resolution0.1 °C
Accuracy±(1.5 % + 5 digits)
  
Measuring range600 ... 1000 °C
Resolution1 °C
Accuracy±(1.5 % + 5 digits)
  
Measuring range-40 ... 600.0 °F
Resolution0.1 °F
Accuracy±(1.5 % + 9 digits)
  
Measuring range600 ... 1800 °F
Resolution1 °F
Accuracy±(1.5 % + 9 digits)
  
Overvoltage protection1000 V AC/DC
  
The accuracy refers to the measuring device without temperature probe.
Specifications refer to a stable ambient condition of ±1 °C.
If the measurement lasts for a long time, the measured value increases by 2 °C
  
Further specifications 
Clamp opening
34 mm / 1.3"
NCV>150 V AC
DisplayLC colour display
Display when measuring range exceeded  "OL" (overload)
Measuring rate3 measured values per second
InterfaceBluetooth
Operating conditions5 ... 40 °C / 41 ... 104 °F
 <80 % RH non-condensing at
 31 °C / 87 °F linearly decreasing to 50 % RH
 non-condensing at 40 °C / 104 °F
Storage conditions-20 ... 40 °C / -4 ... 140 °F <80 % RH
  non-condensing
Maximum working height2000 m / 7000 ft
Power supply3 x 1.5 V AAA batteries
Auto power offSwitched off, 15, 30, 45, 60 minutes
Dimensions250 x 80 x 40 mm / 9.8 x 3.1 x 1.5"
Weight365 g / 12.8 oz

Delivery Scope:

1 x Clamp Meter PCE-DC 25
1 x Pair of test leads
1 x Type K thermocouple
Clamp Meter, Clamp Meter in Pakistan,