Isolation test | Terminal voltage | Measuring range | Resolution | Accuracy | Load current | Short circuit current | 125V (0 ... 10 %) | 0,125 ... 4 MΩ | 0.001 MΩ | ± (2% + 10 digits) | 1-mA @ Last 125 kΩ | <= 1-mA | 4,001 ... 40 MΩ | 0.01 MΩ | ± (2% + 10 digits) | 40,01 ... 400 MΩ | 0.1 MΩ | ± (4% + 5 digits) | 400,1 ... 1000 MΩ | 1 MΩ | ± (5% + 5 digits) | 250V (0 ... 10 %) | 0,125 ... 4 MΩ | 0.001 MΩ | ± (2% + 10 digits) | 1-mA @ Last 250 kΩ | <= 1-mA | 4,001 ... 40 MΩ | 0.01 MΩ | ± (2% + 10 digits) | 40,01 ... 400 MΩ | 0.1 MΩ | ± (3% + 2 digits) | 400,1 ... 1000 MΩ | 1 MΩ | ± (3% + 2 digits) | 500V (0 ... 10 %) | 0,125 ... 4 MΩ | 0.001 MΩ | ± (2% + 10 digits) | 1-mA @ Last 500 kΩ | <= 1-mA | 4,001 ... 40 MΩ | 0.01 MΩ | ± (2% + 10 digits) | 40,01 ... 400 MΩ | 0.1 MΩ | ± (3% + 2 digits) | 400,1 ... 1000 MΩ | 1 MΩ | ± (4% + 5 digits) | 1000 V (0 ... 10 %) | 0,125 ... 4 MΩ | 0.001 MΩ | ± (3% + 10 digits) | 1-mA @ Last 1 MΩ | <= 1-mA | 4,001 ... 40 MΩ | 0.01 MΩ | ± (2% + 10 digits) | 40,01 ... 400 MΩ | 0.1 MΩ | ± (3% + 2 digits) | 400,1 ... 1000 MΩ | 1 MΩ | ± (4% + 5 digits) | Low Ohm | Measuring range | Resolution | Accuracy | Max. open circuit voltage | Overload protection | 2,000 Ω | 0.001 Ω | ± (1.5% + 30 digits) | 5.8V | 250 Vrms | 20,00 Ω | 0.01 Ω | ± (1.5% + 3 digits) | 5.8V | 250 Vrms | 200,0 Ω | 0.1 Ω | ± (1.5% + 3 digits) | 5.8V | 250 Vrms | 2000 Ω | 1 Ω | ± (1.5% + 5 digits) | 5.8V | 250 Vrms | Continuity tester | Measuring range | Resolution | Max. open circuit voltage | Overload protection | Short circuit current | 2000 Ω | 0.01 Ω | 5.8V | 250 Vrms | >= 200-mA | Grinding resistance | L-PE (Hi-Amp): Load current 4.0 A | Measuring range | Resolution | Accuracy | 0.23 ... 9.99 Ω | 0.01 Ω | ± (4% + 4 digits) | 10.0 ... 99.9 Ω | 0.1 Ω | ± (4% + 4 digits) | 100 ... 999 Ω | 1 Ω | ± (4% + 4 digits) | L-PE (without tripping): Load current 15-mA | Measuring range | Resolution | Accuracy | 0.23 ... 9.99 Ω | 0.01 Ω | ± (5% + 6 digits) | 10.0 ... 99.9 Ω | 0.1 Ω | ± (5% + 6 digits) | 100 ... 999 Ω | 1 Ω | ± (5% + 6 digits) | L-N: Load current 4.0 A | Measuring range | Resolution | Accuracy | 0.23 ... 9.99 Ω | 0.01 Ω | ± (4% + 4 digits) | 10.0 ... 99.9 Ω | 0.1 Ω | ± (4% + 4 digits) | 100 ... 999 Ω | 1 Ω | ± (4% + 4 digits) | RCD Test | RCD (In) | 10-mA, 30-mA, 100-mA, 300-mA, 650-mA, 1 A | Factors | x 1/2, x1, x2, x5 | Accuracy of the tripping time | ± (1% + 1 ms) | Signal form of the test current | Sine (AC), pulse (DC) | Tripping characteristics | G and S | Release time | 0° or 180° | Voltage range | 194 ... 260V AC (50/60 Hz) | Accuracy of current measurement | ± (5% + 2 digits) | RCD Types | Type A, Type B | Voltage measurement | Measuring range | Resolution | Accuracy | 80...500 V AC/DC | 1 V | ± (2 % + 2 digits) | Frequency measurement | Measuring range | Resolution | Accuracy | 45...65 Hz | 1 Hz | ±2 Hz | Grounding measurement | Measuring range | Resolution | Accuracy | 0.00...99.99 Ω | 0.01 Ω | ± (2% + 30 digits) | 100.0...999.9 Ω | 0.1 Ω | ± (2% + 6 digits) | 1000...2000 Ω | 1 Ω | ± (2% + 6 digits) | General specifications | Power supply | 8 x 1.2 ... 1.5V AA batteries | Operating time | ca. 15 h | Measurement category | CAT III 600V | Protection class | IP 65 | Display | 3.5" TFT (320 x 240 Pixel) | Operating environment | 0 ... 45°C 0 ... 95% rH, non condensing | Measurements | 24.2 x 10.5 x 14.5 cm | Weight | 1.56 kg / 3.4 lbs |
|