Earth Tester / Earth Resistance Meter PCE-ET 5000 in Pakistan
- Brand: PCE Instruments Germany
- Product Code: PCE-ET 5000
- Availability: Pre-Order
-
Rs.0
Grounding meter with memory / Mobile use possible thanks to battery / Resistance measurement / Protective conductor test / Visual connection aid / Lightning conductor test / Backlight Testing of disturbing voltages, frequencies, and currents.
Specification:
3-pole earth resistance | |
Test voltage | 20, 48V AC |
Test frequency | 94 Hz, 105 Hz, 111 Hz, 128 Hz, AFC |
Short circuit current | 250-mA |
Test time | 26 seconds |
Probe resistance Rs | <100 kΩ |
Auxiliary earth resistance Rh | <100 kΩ |
Resolution | 0.001 Ω |
Measuring range Re | 0.02 Ω ... 300 kΩ |
Accuracy | ± (5% + 10 digits) |
Ust | < 24V |
Fst | 16 ... 400 Hz |
The accuracy is ensured in an environment of 0 ... 28°C / 32 ... 82°F, < 80% RH (non-condensing). Response time < 15 seconds (Time required to reach the specified accuracy, after the start of the measurement with the average function switched off.) | |
4-pole grounding resistor | |
Test voltage | 20, 48V AC |
Test frequency | 94 Hz, 105 Hz, 111 Hz, 128 Hz, AFC |
Short circuit current | 250-mA |
Test time | 30 seconds |
Probe resistance Rs | < 100 kΩ |
Auxiliary earth resistance Rh | < 100 kΩ |
Resolution | 0.001 Ω |
Measuring range Re | 0.02 Ω ... 300 kΩ |
Accuracy | ± (5% + 10 digits) |
Ust | < 24V |
Fst | 16 ... 400 Hz |
The accuracy is ensured in an environment of 0 ... 28°C / 32 ... 82°F, < 80% RH (non-condensing). Response time < 25 seconds (Time required to reach the specified accuracy, after the start of the measurement with the average function switched off.) | |
3-pole earth resistance with current clamp | |
Test voltage | 20, 48V AC |
Test frequency | 94 Hz, 105 Hz, 111 Hz, 128 Hz, AFC |
Short circuit current | 250-mA |
Test time | 26 seconds |
Probe resistance Rs | < 100 kΩ |
Auxiliary earth resistance Rh | < 100 kΩ |
Resolution | 0.001 Ω |
Measuring range Re | 0.02 Ω ... 20 kΩ |
Accuracy | ± (5% + 10 digits) |
Ust | < 24V |
Fst | 16 ... 400 Hz |
The accuracy is ensured in an environment of 0 ... 28°C / 32 ... 82°F, < 80% RH (non-condensing). Response time < 25 seconds (Time required to reach the specified accuracy, after the measurement has started with the average function switched off.) If the current on the current probe is too low, the measurement can be aborted. | |
4-pole earth resistance with current clamp | |
Test voltage | 20, 48V AC |
Test frequency | 94 Hz, 105 Hz, 111 Hz, 128 Hz, AFC |
Short circuit current | 250-mA |
Test time | 26 seconds |
Probe resistance Rs | < 100 kΩ |
Auxiliary earth resistance Rh | < 100 kΩ |
Resolution | 0.001 Ω |
Measuring range Re | 0.02 Ω ... 20 kΩ |
Accuracy | ± (5% + 10 digits) |
Ust | < 24V |
Fst | 16 ... 400 Hz |
The accuracy is ensured in an environment of 0 ... 28°C / 32 ... 82°F, < 80% RH (non-condensing). Response time < 25 seconds (Time required to reach the specified accuracy, after the measurement has started with the average function switched off.) If the current on the current probe is too low, the measurement can be aborted. | |
Grounding resistor only with current clamps | |
Test voltage | 48V AC |
Test frequency | 94 Hz, 105 Hz, 111 Hz, 128 Hz, AFC |
Short circuit current | 250-mA |
Test time | 26 seconds |
Measuring range Re | 0.02 Ω ... 150 Ω |
Resolution | 0.001 Ω |
Accuracy | ± (5% + 10 digits) |
Ust | < 24V |
Fst | 16 ... 400 Hz |
The accuracy is ensured in an environment of 0 ... 28°C / 32 ... 82°F, < 80% RH (non-condensing). Response time < 25 seconds (Time required to reach the specified accuracy, after the measurement has started with the average function switched off.) If the current on the current probe is too low, the measurement can be aborted. | |
Soil resistance (removal resistance) | |
Test voltage | 20, 48V AC |
Test frequency | 94 Hz, 105 Hz, 111 Hz, 128 Hz, AFC |
Short circuit current | 250-mA |
Test time | 26 seconds |
Resolution | 0.001 Ω * m |
Measuring range Re | 0.02 Ω ... 1000 kΩ * m |
Accuracy | ± (5% + 10 digits) |
2-pole resistance measurement (AC) | |
Test voltage | 20V AC |
Test frequency | 94 Hz, 105 Hz, 111 Hz, 128 Hz, AFC |
Short circuit current | 250-mA |
Test time | 26 seconds |
Measuring range Re | 0.02 Ω ... 300 kΩ |
Resolution | 0.001 Ω |
Accuracy | ± (5% + 10 digits) |
Ust | < 24V |
Fst | 16 ... 400 Hz |
2-pole resistance measurement (DC) | |
Test voltage | 20V DC |
Short circuit current | 250-mA |
Test time | 26 seconds |
Measuring range Re | 0.02 ... 3 kΩ |
Resolution | 0.001 Ω |
Accuracy | ± (5% + 10 digits) |
Ust | < 3V |
Fst | 16 ... 400 Hz |
4-pole resistance measurement (DC) | |
Test voltage | 20V DC |
Short circuit current | 250-mA |
Test time | 26 seconds |
Measuring range Re | 0.02 Ω ... 3 kΩ |
Resolution | 0.001 Ω |
Accuracy | ± (5% + 10 digits) |
Ust | < 3V |
Fst | 16 ... 400 Hz |
Line compensation | |
Test voltage | 20, 48V AC |
Test frequency | 94 Hz, 105 Hz, 111 Hz, 128 Hz, AFC |
Short circuit current | 250-mA |
Test time | 26 seconds |
Resolution | 0.001 Ω |
Measuring range Re | 0.02 Ω ... 30 Ω |
Accuracy | ± (3% + 10 digits) |
Ust | < 24V |
Fst | 16 ... 400 Hz |
Interference voltage | |
Measuring range | ± 50V DC |
1 ... 50V AC | |
Resolution | 0.1V |
Accuracy | ± (5% + 5 digits) |
Interference current | |
Measuring range | 20-mA ... 2 A |
Resolution | 1-mA |
Accuracy | ± (5% + 5 digits) |
Interference frequency | |
Measuring range | 16 ... 400 Hz |
Resolution | 1 Hz |
Accuracy | ± (1% + 10 digits) |
Other specifications | |
Data storage | 100 readings |
Operating conditions | 0 ... 40°C / 32 ... 104°F, < 80% RH (non-condensing) |
Charge ambient conditions to the battery | 10 ... 40°C / 50 ... 104°F, < 80% rh (non-condensing) |
Storage conditions | -10 ... 50°C / 50 ... 122°F, < 90% rh (non-condensing) |
Storage conditions for the battery | -20 ... 30°C / -4 ... 86°F, < 80% rh (non-condensing) |
Storage height | < 12,000 m / 39,370 ft |
Operating altitude | < 2,000 m / 6,561 ft |
Clamp diameter | 51 mm |
Display | Backlit LCD, 9,999 digits |
Display measuring range exceeded | > LIMIT |
Display below measuring range | - |
Measuring frequency earthing resistance / leakage current | 1 Hz (If the average value function is activated: one value every four seconds) |
Measuring frequency voltage measurement | 2 Hz |
Measuring frequency interference voltage | 4 Hz |
Measuring frequency interference frequency
Tags: Earth Tester, Earth Resistance Meter, |