Digital multimeter for the stationary workplace / Various measurement functions / High measuring ranges / PASS / FAIL function for component testing / HOLD function / Connection of two thermocouples simultaneously / Software / USB interface.
Specification:
AC voltage | ||
Measuring range | Resolution | Accuracy |
60 mV | 0.001 mV | ± (0.6% 60 digits) @ 45 Hz ... 1 kHz |
600 mV | 0.01 mV | ± (0.3% 30 digits) @ 45 Hz ... 1 kHz |
6V | 0.0001V | ± (0.3% 30 digits) @ 45 Hz ... 1 kHz |
60V | 0.001V | ± (0.3% 30 digits) @ 45 Hz ... 1 kHz |
600V | 0.01V | ± (0.4% 30 digits) @ 45 Hz ... 1 kHz |
1000V | 0.1V | ± (0.6% 30 digits) @ 45 Hz ... 1 kHz |
Input impedance:> 10MΩ | ||
Surge protection: 1000V | ||
Display: True RMS in the measuring range of 10 ... 100% of the respective measuring range | ||
DC voltage | ||
Measuring range | Resolution | Accuracy |
60 mV | 0.001 mV | ± (0.025% + 20 digits) |
600 mV | 0.01 mV | ± (0.025% + 5 digits) |
6V | 0.0001V | ± (0.025% + 5 digits) |
60V | 0.001V | ± (0.025% + 5 digits) |
600V | 0.01V | ± (0.003% + 5 digits) |
1000V | 0.1V | ± (0.003% + 5 digits) |
Input impedance:> 10MΩ | ||
Surge protection: 1000V | ||
AC voltage + DC voltage | ||
Measuring range | Resolution | Accuracy |
60 mV | 0.001 mV | ± (1% + 80 digits) @ 50 Hz ... 1 kHz |
600 mV | 0.01 mV | ± (1% + 80 digits) @ 50 Hz ... 1 kHz |
6V | 0.0001V | ± (1% + 80 digits) @ 50 Hz ... 1 kHz |
60V | 0.001V | ± (1% + 80 digits) @ 50 Hz ... 1 kHz |
600V | 0.01V | ± (1% + 80 digits) @ 50 Hz ... 1 kHz |
1000V | 0.1V | ± (1.2% + 80 digits) @ 50 Hz ... 1 kHz |
Input impedance:> 10MΩ | ||
Surge protection: 1000V | ||
Display: True RMS in the measuring range of 10 ... 100% of the respective measuring range | ||
Alternating current | ||
Measuring range | Resolution | Accuracy |
600 µA | 0.01 µA | ± (0.6% + 40 digits) @ 45 Hz ... 1 kHz |
6000 µA | 0.1 µA | ± (0.6% + 20 digits) @ 45 Hz ... 1 kHz |
60-mA | 0.001-mA | ± (0.6% + 40 digits) @ 45 Hz ... 1 kHz |
600-mA | 0.01-mA | ± (0.6% + 20 digits) @ 45 Hz ... 1 kHz |
10 A | 0.001 A | ± (1% + 20 digits) @ 45 Hz ... 1 kHz |
Display: True RMS in the measuring range of 10 ... 100% of the respective measuring range | ||
Overload protection: µA and mA Measurement: Fuse F 0.6 A 1000V Ø6 x 32 mm | ||
10 A measurement: F 11 A 1000V Ø 10 x 38 mm | ||
When measuring almost 20 A, the measurement time should not be longer than 30 seconds. | ||
After the measurement, the measuring device must rest for approx. 10 minutes. | ||
Direct current | ||
Measuring range | Resolution | Accuracy |
600 µA | 0.01 µA | ± (0.8% + 20 digits) |
6000 µA | 0.1 µA | ± (0.8% + 10 digits) |
60-mA | 0.001-mA | ± (0.8% + 20 digits) |
600-mA | 0.01-mA | ± (0.15% + 10 digits) |
10 A | 0.001 A | ± (0.5% + 10 digits) |
Overload protection: µA and mA Measurement: Fuse F 0.6 A 1000V Ø6 x 32 mm | ||
10 A measurement: F 11 A 1000V Ø10 x 38 mm | ||
A measurement of almost 20 A should not take longer than 30 seconds. | ||
After the measurement, the measuring device must rest for approx. 10 minutes. | ||
AC + DC | ||
Measuring range | Resolution | Accuracy |
600 µA | 0.01 µA | ± (0.8% + 40 digits) @ 50 Hz ... 1 kHz |
6000 µA | 0.1 µA | ± (0.8% + 20 digits) @ 50 Hz ... 1 kHz |
60-mA | 0.001-mA | ± (0.8% + 40 digits) @ 50 Hz ... 1 kHz |
600-mA | 0.01-mA | ± (0.8% + 20 digits) @ 50 Hz ... 1 kHz |
10 A | 0.001 A | ± (1.2% + 20 digits) @ 50 Hz ... 1 kHz |
Display: True RMS in the measuring range of 10 ... 100% of the respective measuring range | ||
Overload protection: µA and mA Measurement: Fuse F 0.6 A 1000V Ø6 x 32 mm | ||
10 A measurement: F 11 A 1000V Ø10 x 38 mm | ||
A measurement of almost 20 A should not take longer than 30 seconds. | ||
After the measurement, the measuring device must rest for approx. 10 minutes. | ||
Resistance | ||
Measuring range | Resolution | Accuracy |
600 Ω | 0.01Ω | In REL mode: ± (0.05% + 10 digits) |
6 kΩ | 0.0001 kΩ | ± (0.05% + 2 digits) |
60 kΩ | 0.001 kΩ | ± (0.05% + 2 digits) |
600 kΩ | 0.01 kΩ | ± (0.05% + 2 digits) |
6 MΩ | 0.0001 MΩ | ± (0.3% + 10 digits) |
60 MΩ | 0.001 MΩ | ± (2% +10 digits) |
Surge protection: 1000 V | ||
With a measuring range of 60 MΩ the ambient humidity should be < 50%. | ||
Conductivity | ||
Measuring range | Resolution | Accuracy |
60 nS | 0.01 nS | ± (2% + 10 digits) |
Surge protection: 1000V | ||
The ambient humidity for the measuring range should be < 50%. | ||
Capacity measurement | ||
Measuring range | Resolution | Accuracy |
6 nF | 0.001 nF | ± (3% + 10 digits) |
60 nF | 0.01 nF | ± (2.5% + 5 digits) |
600 nF | 0.1 nF | ± (2% + 5 digits) |
6 μF | 0.001 μF | ± (2% + 5 digits) |
60 μF | 0.01 μF | ± (2% + 5 digits) |
600 μF | 0.1 μF | ± (2% + 5 digits) |
6 mF | 1 μF | ± (5% + 5 digits) |
60 mF | 10 μF | for reference only |
Surge protection: 1000 V | ||
Temperature | ||
Measuring range | Resolution | Accuracy |
-40 ... 40°C | 1°C | ± (2.0% + 30 digits) |
40 ... 400°C | 1°C | ± (1.0% + 30 digits) |
100 ... 1000°C | 1°C | ± 2.5% |
-40 ... 104°F | 1.8°F | ± (2.5% + 50 digits) |
104 ... 752°F | 1.8°F | ± (1.5% + 50 digits) |
752 ... 1832°F | 1.8°F | ± 2.5% |
Surge protection: 1000V | ||
Two-channel temperature measurement | ||
Temperature sensor: Type K only applies to the measurement of temperatures below 230°C / 446°F | ||
Frequency measurement | ||
Measuring range | Resolution | Accuracy |
60 Hz | 0.001 Hz | ± (0.02% + 8 digits) |
600 Hz | 0.01 Hz | ± (0.01% + 5 digits) |
6 kHz | 0.0001 kHz | ± (0.01% + 5 digits) |
60 kHz | 0.00 1kHz | ± (0.01% + 5 digits) |
600 kHz | 0.01 kHz | ± (0.01% + 5 digits) |
6 MHz | 0.0001 MHz | ± (0.01% + 5 digits) |
60 MHz | 0.00 1MHz | ± (0.01% + 5 digits) |
Surge protection: 1000V | ||
Input amplitude: 10 Hz ... 30 MHz: 600 mV <a <30 Vrm,> 30 MHz: not specified | ||
Duty cycle | ||
Measuring range | Resolution | Accuracy |
10 ... 90% @ | 0.01% | ± (1.2% + 30 digits) |
(10Hz ... 2kHz) | ||
Surge protection: 1000V | ||
Rise time: <1 µs, the signal is centered on the trigger level | ||
Pulse width | ||
Measuring range | Resolution | Accuracy |
250 mS | 0.001 ... 0.1 mS | Digital Multimeter, Digital Multimeter in Pakistan, |