Digital Multimeter PCE-BDM 20 in Pakistan

Digital Multimeter PCE-BDM 20 in Pakistan

  • Rs.0



Digital multimeter for the stationary workplace / Various measurement functions /  High measuring ranges / PASS / FAIL function for component testing / HOLD function / Connection of two thermocouples simultaneously / Software / USB interface.

Specification:

AC voltage 
Measuring rangeResolutionAccuracy
60 mV0.001 mV± (0.6% 60 digits) @ 45 Hz ... 1 kHz
600 mV0.01 mV± (0.3% 30 digits) @ 45 Hz ... 1 kHz
6V0.0001V± (0.3% 30 digits) @ 45 Hz ... 1 kHz
60V0.001V± (0.3% 30 digits) @ 45 Hz ... 1 kHz
600V0.01V± (0.4% 30 digits) @ 45 Hz ... 1 kHz
1000V0.1V± (0.6% 30 digits) @ 45 Hz ... 1 kHz
Input impedance:> 10MΩ
Surge protection: 1000V
Display: True RMS in the measuring range of 10 ... 100% of the respective measuring range
   
DC voltage
Measuring rangeResolutionAccuracy
60 mV0.001 mV± (0.025% + 20 digits)
600 mV0.01 mV± (0.025% + 5 digits)
6V0.0001V± (0.025% + 5 digits)
60V0.001V± (0.025% + 5 digits)
600V0.01V± (0.003% + 5 digits)
1000V0.1V± (0.003% + 5 digits)
Input impedance:> 10MΩ
Surge protection: 1000V
   
AC voltage + DC voltage
Measuring rangeResolutionAccuracy
60 mV0.001 mV± (1% + 80 digits) @ 50 Hz ... 1 kHz
600 mV0.01 mV± (1% + 80 digits) @ 50 Hz ... 1 kHz
6V0.0001V± (1% + 80 digits) @ 50 Hz ... 1 kHz
60V0.001V± (1% + 80 digits) @ 50 Hz ... 1 kHz
600V0.01V± (1% + 80 digits) @ 50 Hz ... 1 kHz
1000V0.1V± (1.2% + 80 digits) @ 50 Hz ... 1 kHz
Input impedance:> 10MΩ
Surge protection: 1000V
Display: True RMS in the measuring range of 10 ... 100% of the respective measuring range
   
Alternating current
Measuring rangeResolutionAccuracy
600 µA0.01 µA± (0.6% + 40 digits) @ 45 Hz ... 1 kHz
6000 µA0.1 µA± (0.6% + 20 digits) @ 45 Hz ... 1 kHz
60-mA0.001-mA± (0.6% + 40 digits) @ 45 Hz ... 1 kHz
600-mA0.01-mA± (0.6% + 20 digits) @ 45 Hz ... 1 kHz
10 A0.001 A± (1% + 20 digits) @ 45 Hz ... 1 kHz
Display: True RMS in the measuring range of 10 ... 100% of the respective measuring range
Overload protection: µA and mA Measurement: Fuse F 0.6 A 1000V Ø6 x 32 mm
10 A measurement: F 11 A 1000V Ø 10 x 38 mm
When measuring almost 20 A, the measurement time should not be longer than 30 seconds.
After the measurement, the measuring device must rest for approx. 10 minutes.
   
Direct current
Measuring rangeResolutionAccuracy
600 µA0.01 µA± (0.8% + 20 digits)
6000 µA0.1 µA± (0.8% + 10 digits)
60-mA0.001-mA± (0.8% + 20 digits)
600-mA0.01-mA± (0.15% + 10 digits)
10 A0.001 A± (0.5% + 10 digits)
Overload protection: µA and mA Measurement: Fuse F 0.6 A 1000V Ø6 x 32 mm
10 A measurement: F 11 A 1000V Ø10 x 38 mm
A measurement of almost 20 A should not take longer than 30 seconds.
After the measurement, the measuring device must rest for approx. 10 minutes.
   
AC + DC
Measuring rangeResolutionAccuracy
600 µA0.01 µA± (0.8% + 40 digits) @ 50 Hz ... 1 kHz
6000 µA0.1 µA± (0.8% + 20 digits) @ 50 Hz ... 1 kHz
60-mA0.001-mA± (0.8% + 40 digits) @ 50 Hz ... 1 kHz
600-mA0.01-mA± (0.8% + 20 digits) @ 50 Hz ... 1 kHz
10 A0.001 A± (1.2% + 20 digits) @ 50 Hz ... 1 kHz
Display: True RMS in the measuring range of 10 ... 100% of the respective measuring range
Overload protection: µA and mA Measurement: Fuse F 0.6 A 1000V Ø6 x 32 mm
10 A measurement: F 11 A 1000V Ø10 x 38 mm
A measurement of almost 20 A should not take longer than 30 seconds.
After the measurement, the measuring device must rest for approx. 10 minutes.
   
Resistance
Measuring rangeResolutionAccuracy
600 Ω0.01ΩIn REL mode: ± (0.05% + 10 digits)
6 kΩ0.0001 kΩ± (0.05% + 2 digits)
60 kΩ0.001 kΩ± (0.05% + 2 digits)
600 kΩ0.01 kΩ± (0.05% + 2 digits)
6 MΩ0.0001 MΩ± (0.3% + 10 digits)
60 MΩ0.001 MΩ± (2% +10 digits)
Surge protection: 1000 V
With a measuring range of 60 MΩ the ambient humidity should be < 50%.
   
Conductivity
Measuring rangeResolutionAccuracy
60 nS0.01 nS± (2% + 10 digits)
Surge protection: 1000V
The ambient humidity for the measuring range should be < 50%.
   
Capacity measurement
Measuring rangeResolutionAccuracy
6 nF0.001 nF± (3% + 10 digits)
60 nF0.01 nF± (2.5% + 5 digits)
600 nF0.1 nF± (2% + 5 digits)
6 μF0.001 μF± (2% + 5 digits)
60 μF0.01 μF± (2% + 5 digits)
600 μF0.1 μF± (2% + 5 digits)
6 mF1 μF± (5% + 5 digits)
60 mF10 μFfor reference only
Surge protection: 1000 V
   
Temperature
Measuring rangeResolutionAccuracy
-40 ... 40°C1°C± (2.0% + 30 digits)
40 ... 400°C1°C± (1.0% + 30 digits)
100 ... 1000°C1°C± 2.5%
-40 ... 104°F1.8°F± (2.5% + 50 digits)
104 ... 752°F1.8°F± (1.5% + 50 digits)
752 ... 1832°F1.8°F± 2.5%
Surge protection: 1000V
Two-channel temperature measurement
Temperature sensor: Type K only applies to the measurement of temperatures below 230°C / 446°F
   
Frequency measurement
Measuring rangeResolutionAccuracy
60 Hz0.001 Hz± (0.02% + 8 digits)
600 Hz0.01 Hz± (0.01% + 5 digits)
6 kHz0.0001 kHz± (0.01% + 5 digits)
60 kHz0.00 1kHz± (0.01% + 5 digits)
600 kHz0.01 kHz± (0.01% + 5 digits)
6 MHz0.0001 MHz± (0.01% + 5 digits)
60 MHz0.00 1MHz± (0.01% + 5 digits)
Surge protection: 1000V
Input amplitude: 10 Hz ... 30 MHz: 600 mV <a <30 Vrm,> 30 MHz: not specified
   
Duty cycle
Measuring rangeResolutionAccuracy
10 ... 90% @0.01%± (1.2% + 30 digits)
(10Hz ... 2kHz)  
Surge protection: 1000V
Rise time: <1 µs, the signal is centered on the trigger level
   
Pulse width
Measuring rangeResolutionAccuracy
250 mS0.001 ... 0.1 mSDigital Multimeter, Digital Multimeter in Pakistan,