Current clamp PCE-PCM 3 Digital multimeter for single-phase measurement / NCV measurement / W / VA / Var / Inrush Current / 1000 A AC Current Measurement / Bluetooth Interface / Frequency Measurement / Backlight / Voltage measurement / 750 kW power.
Specification:
Ambient conditions 23°C / 73.4°F ± 5°C / 41°F, < 75% RH | ||
Measuring function | ||
Current measurement AC | ||
Measuring range | Resolution | Accuracy |
60 A | 0.01 A | ± 2% + 8 Dgt |
600 A | 0.1 A | ± 2% + 8 Dgt |
1000 A | 1 A | ± 2% + 8 Dgt |
Maximum input current: 1000 A AC | ||
Frequency range: 40 .... 400 Hz | ||
Measuring function | ||
Inrush current AC | ||
Measuring range | Resolution | Accuracy |
60 A | 0.01 A | For reference only |
600 A | 0.1 A | ± 5% + 60 Dgt |
1000 A | 1 A | ± 5% + 60 Dgt |
Integral time: 100 ms | ||
Measuring range: 20 ... 1000 A | ||
Frequency range: 40 .... 400 Hz | ||
Measuring function | ||
Voltage measurement DC | ||
Measuring range | Resolution | Accuracy |
6V | 0.001V | ± 0.5% + 5 Dgt |
60V | 0.01V | ± 0.5% + 5 Dgt |
600V | 0.1V | ± 0.5% + 5 Dgt |
1000V | 1V | ± 0.8% + 4 Dgt |
Input impedance: 10 MΩ | ||
Maximum input voltage: 750V AC (rms value) or 1000V DC | ||
Measuring function | ||
Voltage measurement AC | ||
Measuring range | Resolution | Accuracy |
6V | 0.001V | ± 0.6% + 4 Dgt |
60V | 0.01V | ± 0.6% + 4 Dgt |
600V | 0.1V | ± 0.6% + 4 Dgt |
1000V | 1V | ± 0.8% + 4 Dgt |
Input impedance: 10 MΩ | ||
Maximum input voltage: 750V AC (rms value) or 1000V DC | ||
Frequency range: 40 ... 400 Hz | ||
Measuring function | ||
Frequency measurement with | ||
The current measuring function | ||
Measuring range | Resolution | Accuracy |
99.99 Hz | 0.01 Hz | ± 1.5% + 5 Dgt |
999.9 Hz | 0.1 Hz | ± 1.5% + 5 Dgt |
Measuring range: 10 ... 1 kHz | ||
Measuring range of the input signal: > 20 AAC (rms value) | ||
The input current increases with the measuring frequency. | ||
Maximum input current: 1000 AAC (rms value) | ||
Measuring function | ||
Frequency measurement with the | ||
Voltage measurement function | ||
Measuring range | Resolution | Accuracy |
99.99 Hz | 0.01 Hz | ± 1.5% + 5 Dgt |
999.9 Hz | 0.1 Hz | ± 1.5% + 5 Dgt |
9,999 kHz | 0.001 kHz | ± 1.5% + 5 Dgt |
Measuring range: 10 ... 10 kHz | ||
Measuring range of the input signal: > 1V AC (rms value) | ||
The input current increases with the measuring frequency. | ||
Maximum input voltage: 1000V AC (rms value) | ||
Measuring function | ||
Frequency measurement | ||
Measuring range | Resolution | Accuracy |
9,999 Hz | 0.001 Hz | ± 0.3% + 5 Dgt |
99.99 Hz | 0.01 Hz | ± 0.3% + 5 Dgt |
9,999 kHz | 0.1 Hz | ± 0.3% + 5 Dgt |
999.9 Hz | 0.001 kHz | ± 0.3% + 5 Dgt |
99.99 kHz | 0.01 kHz | ± 0.3% + 5 Dgt |
999.9 kHz | 0.1 kHz | ± 0.3% + 5 Dgt |
9,999 MHz | 0.001 MHz | ± 0.3% + 5 Dgt |
Overvoltage protection: 1000V DC or 750V AC (rms value) | ||
Range of voltage input> 2V | ||
(as the input voltage increases, so does the frequency) | ||
Measuring function | ||
Duty cycle | ||
Measuring range | Resolution | Accuracy |
0.1 ... 99.9% | 0.1% | ± 0.3% + 5 Dgt |
Frequency range: 10 ... 10 kHz | ||
Voltage range: 2 ... 250V AC (rms value) | ||
(The voltage increases with the frequency) | ||
Duty cycle with the | Frequency range: 10 ... 1 kHz | |
Current measurement function | Input current: 20 ... 1000 AAC (rms value) | |
Duty cycle with the | Frequency range: 10 ... 1 kHz | |
Voltage measurement function | Input current: 1 ... 750V AC (rms value) | |
Input impedance: 1MΩ | ||
Measuring function | ||
Resistivity | ||
Measuring range | Resolution | Accuracy |
600 Ω | 0.1 Ω | ± 0.8% + 3 Dgt |
6 kΩ | 0.001 kΩ | ± 0.8% + 3 Dgt |
60 kΩ | 0.01 kΩ | ± 0.8% + 3 Dgt |
600 kΩ | 0.1 kΩ | ± 0.8% + 3 Dgt |
6 MΩ | 0.001 MΩ | ± 2% + 5 Dgt |
60 MΩ | 0.1 MΩ | ± 2% + 5 Dgt |
Measuring voltage: approx. 0.78V | ||
Overvoltage protection: 750V DC, 1000V AC (rms value) | ||
Measuring function | ||
Continuity test | ||
Measuring range | Resolution | Accuracy |
600 Ω | 0.1 Ω | - |
Acoustic signal at < 50 Ω | ||
Test voltage: 1.48V | ||
Overvoltage protection: 750V DC, 1000V AC (rms value) | ||
Measuring function | ||
Capacitance measurement | ||
Measuring range | Resolution | Accuracy |
9.999 nF | 0.001 nF | ± 3% + 5 Dgt |
99.99 n.f. | 0.01 nF | ± 3% + 5 Dgt |
999.9 nF | 0.1 nF | ± 3% + 5 Dgt |
9.999 μF | 0.001 μF | ± 3% + 5 Dgt |
99.99 μF | 0.01 μF | ± 3% + 5 Dgt |
999.9 μF | 0.1 μF | ± 3% + 5 Dgt |
9,999mF | 0.001 mF | ± 3% + 5 Dgt |
99.99 mF | 0.01 mF | ± 3% + 5 Dgt |
Overvoltage protection: 750V DC, 1000V AC (rms value) | ||
Measuring function | ||
Diode measurement | ||
Measuring range | Resolution | Accuracy |
3V | 0.001V | - |
DC anode side: approx. 1-mA | ||
DC cathode side: approx. 3.2V | ||
Overvoltage protection: 750V DC, 1000V AC (rms value) |