Clamp meter with true rms measurement / AC current measurement / Voltage measurement / Temperature measurement / Bluetooth interface / Rubberized housing / Display hold / Automatic switch-off / Test lead max. 48 mm / Many measuring functions.

Specification:

Current measurement DC A  
Measuring rangeResolutionAccuracy (of rdg.)
500 μA0.01 μA± (1% + 6 digits)
5000 μA0.1 μA± (1% + 6 digits)
50 A0.01A± (2.5% + 5 digits)
1000 A0.1 A± (2.5% + 30 digits)
   
Current measurement AC A  
Measuring rangeResolutionAccuracy (of rdg.)
500 μA0.01 μA± (1.5% + 30 digits)
5000 μA0.1 μA± (1.5% + 30 digits)
50 A0.01A± (2.5% + 30 digits)
1000 A0.1 A± (2.8% + 30 digits)
   
Note: For AC A measurements, the specification of accuracy refers to the range of 5% to 100% of the measuring range
   
Resistivity  
Measuring rangeResolution Accuracy (of rdg.)
500 Ω0.01± (1% + 9 digits)
5 kΩ0.0001± (1% + 5 digits)
50 kΩ0.001± (1% + 5 digits)
500 kΩ0.01± (1% + 5 digits)
5 MΩ0.0001± (3% + 10 digits)
50 MΩ0.001± (3.5% + 10 digits)
   
Voltage measurement DC V  
Measuring rangeResolutionAccuracy (of rdg.)
500 mV0.01 mV± (0.1% + 8 digits)
5V0.0001V± (0.1% + 4 digits)
50V0.001 V± (0.1% + 4 digits)
500V0.01V± (0.1% + 4 digits)
600V0.1V± (0.5% + 4 digits)
   
Voltage measurement AC V (50 Hz ... 1000 Hz)  
measuring rangeResolutionAccuracy (of rdg.)
500 mV0.01 mV

± (0.8% + 9 digits) (at 50 Hz / 60 Hz)

5V0.0001V± (1% + 30 digits)
50V0.001 V± (1% + 30 digits)
500V0.01V± (1% + 30 digits)
600V0.1V± (1% + 30 digits)
   
Note: The accuracy specification for AC V measurements refers to the range of 5% to 100% of the measuring range
   
Capacitance measurement  
Measuring rangeResolutionAccuracy (of rdg.)
500 nF0.01± (3.5% + 40 digits)
5000 nF0.1± (3.5% + 10 digits)
50 μF0.001± (3.5% + 10 digits)
500 μF0.01± (3.5% + 10 digits)
5mF0.0001± (5% + 10 digits)
   
Frequency measurement  
Measuring rangeResolutionAccuracy (of rdg.)
50 Hz0.001± (0.3% + 2 digits)
500 Hz0.01± (0.3% + 2 digits)
5 kHz0.0001± (0.3% + 2 digits)
50 khz0.001± (0.3% + 2 digits)
500 kHz0.01± (0.3% + 2 digits)
5 Mhz0.0001± (0.3% + 2 digits)
10 MHz0.001± (0.3% + 2 digits)
   
Duty cycle  
Measuring rangeResolutionAccuracy (of rdg.)
5% ... 95%0.1

± (1% + 2 digits) (from the measured value)

   
Pulse width: 100 μs ... 100 ms 
  
Frequency: 10 Hz ... 10 kHz  
   
Temperature  
Measuring rangeResolutionAccuracy (of rdg.)
-100°C ... 1000°C / -148 ... 1832°F0.1± (1% + 2.5°C / 4.5°F)
   
General technical data  
Conductor diameterMax. 48 mm
Display
Two lines 50,000 digits
Continuity test50 ohms / < 50-mA
Diode test0.3-mA / 2.8V DC
Battery indicatorBattery icon when battery low
OverrangeOL, if measuring range exceeded
Sample rate2 Hz
InterfaceBluetooth
Peak detection> 1 ms
ThermocoupleType K
Fuse500-mA ceramic quick-acting
AC bandwidth (AC A / AC V)50 Hz ... 400 Hz
AC measurementTrue RMS
Operating conditions5°C ... 40°C / 41 ... 104°F, max. 80% RH at 31°C
Storage conditions-20°C ... 60°C / -4 ... 140°F, max. 80% rh
Power supply9V block battery
Automatic shutdownAfter about 30 minutes
Dimensions (W x H x D)230 x 76 x 40 mm / 9 x 3 x 1.6 in 
Weight315 g / < 1 lb
SecurityIEC 1010-1 (2001):
EN 61010-1 (2001)
CAT III 600V
CAT II 1000V Degree of
pollution 2


Delivery Scope:

1 x Current clamp PCE-DC 50
1 x Test lead set
1 x Transport case
1 x PC software
1 x Bluetooth adapter
2 x Thermocouples type-K
1 x 9V block battery