Current Clamp PCE-CM 5 in Pakistan
- Brand: PCE Instruments Germany
- Product Code: PCE-CM 5
- Availability: Pre-Order
-
Rs.0
Digital multimeter with NCV measurement / Current measurement up to 200 A AC / Frequency measurement directly at the current clamp / Ready for immediate use / Simple operation.
Specification:
Alternating current | |||
Measuring range | Resolution | Accuracy | |
200 A | 0.1 A | ± (3.0% + 3 digits) | |
Frequency range: 40 ... 400 Hz | |||
Maximum input current: 200 A AC | |||
Direct current | |||
Measuring range | Resolution | Accuracy | |
600 µA | 0.1 µA | ± (1.0% + 4 digits) | |
1000 µA | 1 µA | ± (1.0% + 4 digits) | |
Maximum input current: 1000 µA | |||
DC | |||
Measuring range | Resolution | Accuracy | |
600 mV | 0.1 mV | ± (0.7% + 3 digits) | |
6V | 0.001 V | ± (0.7% + 3 digits) | |
60V | 0.01 V | ± (0.7% + 3 digits) | |
600V | 0.1 V | ± (0.7% + 3 digits) | |
Input impedance: 10 MΩ | |||
maximum input voltage: 600V DC AC rms | |||
AC | |||
Measuring range | Resolution | Accuracy | |
6V | 0.001V | ± (0.8% + 3 digits) | |
60V | 0.01V | ± (0.8% + 3 digits) | |
600V | 0.1V | ± (0.8% + 3 digits) | |
Input impedance: 10 MΩ | |||
Maximum input voltage: 600V DC AC rms | |||
Frequency range: 40 ... 400 Hz | |||
LowZ AC / DC | |||
Measuring range | Resolution | Accuracy | |
600V | 0.1V | ± (2.0% + 3 digits) | |
Input impedance: 10 MΩ | |||
Maximum input voltage: 600V DC AC rmsS | |||
Frequency range: 40 ... 400 Hz | |||
Resistance | |||
Measuring range | Resolution | Accuracy | |
600 Ω | 0.1 Ω | ± (0.8% + 3 digits) | |
6 kΩ | 0.001 kΩ | ± (0.8% + 3 digits) | |
60 kΩ | 0.01 kΩ | ± (0.8% + 3 digits) | |
600 kΩ | 0.1 kΩ | ± (0.8% + 3 digits) | |
6 MΩ | 0.001 MΩ | ± (1.2% + 3 digits) | |
60 MΩ | 0.1 MΩ | ± (1.2% + 3 digits) | |
Test voltage (open circuit): 0.4V | |||
Surge protection: 250V AC / DC rms | |||
Continuity test | |||
Measuring range | Resolution | accuracy | |
- | 0.1 Ω | - | |
Surge protection: 250 V AC / DC rms | |||
Beep at <50 Ω | |||
Diode test | |||
Measuring range | Resolution | Accuracy | |
- | 0.001V | - | |
Surge protection: 250V AC / DC rms | |||
Forward current: 1-mA DC | |||
Forward voltage: 3.3V DC | |||
Capacities | |||
Measuring range | Resolution | Accuracy | |
99.99 nF | 0.01 nF | ± (4.0% + 5 digits) | |
999.9 nF | 0.1 nF | ± (4.0% + 5 digits) | |
9.999 µF | 0.001 µF | ± (4.0% + 5 digits) | |
99.99 µF | 0.01 µF | ± (4.0% + 5 digits) | |
999.9 µF | 0.1 µF | ± (4.0% + 5 digits) | |
9.999 mF | 1 µF | ± (4.0% + 5 digits) | |
99.99 mF | 0.01 mF | ± (4.0% + 5 digits) | |
Surge protection: 250V AC / DC rms | |||
Temperature (thermocouple type K) | |||
Measuring range | Resolution | Accuracy | |
-20 ... 0°C | 1°C | ± (3.0% + 2 digits) | |
1 ... 400°C | 1°C | ± (2.0% + 2 digits) | |
-4 ... 32°F | 1°F | ± (3.0% + 4 digits) | |
33 ... 752°F | 1°F | ± (2.0% + 4 digits) | |
Surge protection: 250V AC / DC rms | |||
Frequency (with current probe) | |||
Measuring range | Resolution | Accuracy | |
99.99 Hz | 0.01 Hz | ± (1.5% + 5 digits) | |
999.9 Hz | 0.1 Hz | ± (1.5% + 5 digits) | |
> 1 kHz | 0.001 kHz | for reference only | |
Frequency range: 10 Hz ... 1 kHz | |||
Maximum input current: 200 A AC rms | |||
Input range: > 60 A AC rms (if the input current increases, the frequency also increases) | |||
Frequency (when measuring voltage) | |||
Measuring range | Resolution | Accuracy | |
99.99 Hz | 0.01 Hz | ± (1.5% + 5 digits) | |
999.9 Hz | 0.1 Hz | ± (1.5% + 5 digits) | |
9.999 Hz | 0.001 kHz | ± (1.5% + 5 digits) | |
> 10 kHz | 0.01 kHz | for reference only | |
Frequency range: 10 Hz ... 10 kHz | |||
Frequency (direct measurement) | |||
Measuring range | Resolution | Accuracy | |
99.99 Hz | 0.01 Hz | ± (0.3% + 5 digits) | |
999.9 Hz | 0.1 Hz | ± (0.3% + 5 digits) | |
9.999 Hz | 1 Hz | ± (0.3% + 5 digits) | |
99.99 kHz | 0.01 kHz | ± (0.3% + 5 digits) | |
999.9 kHz | 0.1 kHz | ± (0.3% + 5 digits) | |
9.999 kHz | 1 kHz | ± (0.3% + 5 digits) | |
99.99 MHz | 0.01 MHz | ± (0.3% + 5 digits) | |
Measuring range: 10 Hz ... 60 MHz | |||
Input impedance: 10 MΩ | |||
Input range:> 0.2V AC rms (the input voltage increases, the frequency also increases) | |||
Maximum input voltage: 250V AC rms | |||
Duty cycle | |||
Measuring range | Resolution | Accuracy | |
5 ... 95% | 0.1% | ± 0.3% | |
More specifications | |||
Range selection | Automatically and manually | ||
Maximum working height | 2000 m / 6561.7 ft | ||
Display | LCD display | ||
Largest display value | 5999 | ||
Overrange | "OL" display | ||
Measuring range underflow | "-OL" display | ||
Measuring rate | 3 measurements per second | ||
Automatic shutdown | After 15 minutes of inactivity | ||
Power supply | 1 x 9V block battery | ||
Operating conditions | 0 ... 40°C / 32 ... 104°F | ||
Storage conditions | -10 ... 50°C / 14 ... 122°F | ||
Dimensions | 201 x 65 x 43 mm / 7.9 x 2.6 x 1.7 in | ||
Weight | Approx. 265 g / < 1 lb (with battery) |
Delivery Scope: