Clamp Meter PCE-CM 3 in Pakistan

Clamp Meter PCE-CM 3 in Pakistan

  • Rs.0



Fork Clamp Up to 200 A AC / AC / DC Voltage Measurement / Simple Current Measurement / LC display / Continuity test / Thermometer.

Specification:

DC  
Measuring rangeResolutionAccuracy
4V DC1 mV± (1.2% of measured value + 2 digits)
40V DC10 mV± (1.5% of measured value + 2 digits)
400V DC100 mV± (1.5% of measured value + 2 digits)
600V DC1V± (2% of measured value + 2 digits)
   
Input impedance10 MΩ 
Overvoltage protection600V DC 
 600V AC RMS 
   
AC  
Measuring rangeResolutionAccuracy
4V AC1 mV± (1.5% of measured value + 5 digits)
40V AC10 mV± (1.5% of measured value + 2 digits)
400V AC100 mV± (1.5% of measured value + 2 digits)
600V AC1 V± (2% of measured value + 2 digits)
   
Input impedance10 MΩ 
Overvoltage protection600V DC 
 600V AC RMS 
Frequency range50 ... 400 Hz 
   
Alternating current  
Measuring rangeResolutionAccuracy
200 A AC100-mA± (3.0% of measured value + 5 digits)
Overload protection200 A AC 
Frequency range50 ... 60 Hz 
   
Resistance  
Measuring rangeResolutionAccuracy
400 Ω0.1 Ω± (1% of measured value + 4 digits)
4 kΩ1 Ω± (1.5% of measured value + 4 digits)
40 kΩ10 Ω± (1.5% of measured value + 4 digits)
400 kΩ100 Ω± (1.5% of measured value + 4 digits)
4 MΩ1 kΩ± (2.5% of measured value + 4 digits)
40 MΩ10 kΩ± (3.5% of measured value + 4 digits)
   
Overvoltage protection250V DC 
 250 AC RMS 
   
Connection thermocoupleType K connection with adapter 
   
Capacity  
Measuring rangeResolutionAccuracy
4 nF0.1 nF± (5% of measured value + 20 digits)
40 nF1 nF± (3% of measured value + 5 digits)
400 nF10 nF± (3% of measured value + 5 digits)
4 μF100 nF± (3% of measured value + 5 digits)
40 μF1 μF± (3% of measured value + 5 digits)
100 μF10 μF± (3% of measured value + 10 digits)
   
Overvoltage protection250V DC 
 250 AC RMS 
   
Check featureTestDisplay
Diode testTest current: 0.5-mA
Reverse Voltage: 1.5V
Forward voltage of the diode
Continuity testOpen circuit Voltage 0.5VNoise when resistance <50 Ω
   
Overvoltage protection250V DC
250 AC RMS
 
   
General technical specifications 
Jaw CapacityAbout 17 mm / .7 in
Display4000 digit LCD with backlight
Continuity testNoise when resistance <50 Ω
Test currentAbout 0.5-mA
Open circuit voltage<2V DC
Battery indicatorBattery icon when battery voltage low
Display overrangeOL appears in the display
Refresh rate display3 Hz
Temperature sensorThermocouple type K
Input impedance10 MΩ
Operating conditions5 ... 40°C / 41 ... 104°F, 80% rh non-condensing
Storage conditions-20 ... 60°C / -4 ... 140°F, 80% rh non-condensing
Operating altitude<2000 m
Power supply2 x 1.5V AAA battery
Automatic shutdown30 minutes
Security conditionsIEC1010-1 (2001)
CAT II 1000V
CAT III 600V
Pollution degree2


Delivery Scope:

1 x Clamp meter PCE-CM 3
2 x Test leads
2 x Measuring tip
1 x Adapter thermocouple
1 x Thermocouple type K
2 x AAA batteries 1.5V
1 x User manual

Download the Data Sheet of PCE-CM 3 

Tags: Clamp Meter, Clamp Meter in Pakistan,