Extech LCR200  Passive Component LCR Meter

Extech LCR200 Passive Component LCR Meter

  • Rs.0



Measures Inductance, Capacitance, and Resistance with secondary parameter (Q,D,R,P,ESR)The LCR200 is a passive component LCR meter. Discover the tremendous value with a range of features that help this meter provide the precise measurements you need. See simultaneous 20,000/2,000 count display of the primary parameter on the high contrast backlit display. You can set Hi/Lo limits using absolute values or percentages. Open and Short Zero removes unwanted stray impedances from the measurement. Use the built-in test fixture or external test leads (included). The LCR200 has an Auto Power Off function that can also be disabled and a low battery indicator to alert you when to replace the batteries. Complete with test leads and 9V battery.

  Passive Component LCR Meter Features:

  • Measures Inductance, Capacitance, and Resistance with secondary parameter Q (Quality), D (Dissipation), R (Resistance), P (Phase), ESR (Equivalent Series Resistance)
  • Simultaneous 20,000/2,000 count backlit display of the primary parameter (L, C or R) with the secondary parameter
  • Auto Select measurement function with 1kHz default test frequency
  • Five test frequencies
  • Set Hi/Lo limits using absolute values or percentage limits
  • Relative mode function
  • Parallel or Series equivalent circuit
  • Auto power off, Low battery and overrange indicators
  • Built-in test fixture or use external test leads
  • Open and Short calibration removes unwanted stray impedances from the measurement
  • Complete with test leads and 9V battery


Specifications                                             Ranges
Inductance                          20μH, 200μH, 2000.0μH, 20.0000mH, 200.00mH
                                              2000.0H, 20.000H, 200.00H, 2000.0H
Capacitance                       20pF, 200pF, 2000pF, 20.000nF, 200.00nF, 2000.0nF
                                              20.000μF, 200.00μF, 2.0000mF, 20.00mF
Resistance                          20.00Ω, 200.00Ω, 2.0000kΩ, 20.000kΩ,
                                              200.00kΩ, 2.0000MΩ, 20.000MΩ, 200.0MΩ
DF (with C)                          0.000 to 999
Q                                           0.000 to 999
Phase                                   ±90°
Test Frequency                  100Hz/120Hz/1kHz/10kHz/100kHz
Dimensions                         7.6 x 3.5 x 1.6” (193 x 88 x 41mm)
Weight                                 14.8oz (420g)


Download Brochure
Download Users Manual


Tags: Passive Component LCR Meter,